رقم الجزء
تجريد
صلاحيه
UOM
NIIN
معلومات الجزء
20.0 kilohertz to 60.0 kilohertz square wave output frequency
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
3.300 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
1.550 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
2.000 inches
MRC:
The maximum altitude at which the item is rated to function.AKAE
Maximum Operating Altitude Rating:
13100.0 feet
MRC:
The relationship of the electrical power source to the item.AKWC
Electrical Power Source Relationship:
Operating
MRC:
The input value/s/,or range of values,for which the item is rated.APNX
Input Voltage Rating:
18.0 dc volts 2nd operating power rqmt and 23.5 dc volts 2nd operating power rqmt
MRC:
The input value/s/,or range of values,for which the item is rated.APNX
Input Voltage Rating:
22.5 dc volts 1st operating power rqmt and 30.0 dc volts 1st operating power rqmt
MRC:
The output value/s/,or range of values,for which the item is rated.APPA
Output Voltage Rating:
18.0 ac volts 2nd power output
MRC:
The output value/s/,or range of values,for which the item is rated.APPA
Output Voltage Rating:
24.0 ac volts 1st power output
MRC:
The ambient temperature range at which the item is designed to operate.AYNH
Operating Ambient Tempurature Range:
-55.0/+100.0 degrees celsius
MRC:
The number of output control(s) provided.BGHX
Output Control Quantity:
1 1st power output
MRC:
The number of output control(s) provided.BGHX
Output Control Quantity:
1 2nd power output
MRC:
Indicates the type of output control provided.BGHY
Output Control Type:
Fixed voltage 1st power output
MRC:
Indicates the type of output control provided.BGHY
Output Control Type:
Fixed voltage 2nd power output
MRC:
The means used to change alternating current voltage to direct current voltage.BHQN
Rectification Method:
Single phase full wave center tap
MRC:
Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
Features Provided:
Filter
MRC:
Indicates the location of the output control(s).CWHC
Output Control Location:
Bottom panel 1st power output
MRC:
Indicates the location of the output control(s).CWHC
Output Control Location:
Bottom panel 2nd power output
MRC:
The number of electrical output connections on the item.CWHF
Output Connection Quantity:
2 2nd power output
MRC:
The number of electrical output connections on the item.CWHF
Output Connection Quantity:
2 1st power output
MRC:
Indicates the type of electrical output connection.CWHJ
Output Connection Type:
Pin plug 2nd power output
MRC:
Indicates the type of electrical output connection.CWHJ
Output Connection Type:
Pin plug 1st power output
MRC:
Indicates the type of electrical input connection.CWHQ
Input Connection Type:
Pin plug 1st operating power rqmt
MRC:
Indicates the type of electrical input connection.CWHQ
Input Connection Type:
Pin plug 2nd operating power rqmt
MRC:
The number of electrical input connections on the item.CWHT
Input Connection Quantity:
2 1st operating power rqmt
MRC:
The number of electrical input connections on the item.CWHT
Input Connection Quantity:
2 2nd operating power rqmt