رقم الجزء
تجريد
صلاحيه
UOM
NIIN
TXT
وصف:
Direct Current Motor
MRC:
The distance measured in a straight line from the bottom to the top of an item.AAJT
Overall Height:
3.750 inches
MRC:
A measurement of the longest dimension of an item,in distinction from width.AAJU
Overall Length:
5.562 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.AAJV
Overall Width:
3.000 inches
MRC:
The measurement between specified points of the slot,in distinction from height.AAZT
Slot Depth:
0.219 inches identical ends
MRC:
The distance,measured along a straight line perpendicular to the longitudinal axis of the slot,from one edge to the other.ABGC
Slot Width:
0.125 inches identical ends
MRC:
The length of a straight line which passes through the center of a shaft,and terminates at the circumference.ABWV
Shaft Diameter:
0.3120 inches first end
MRC:
The length of a straight line which passes through the center of a shaft,and terminates at the circumference.ABWV
Shaft Diameter:
0.3120 inches second end
MRC:
The direction of rotation of a rotating shaft as viewed from the drive end.AKCT
Shaft Rotation Direction:
Clockwise identical ends or counterclockwise identical ends
MRC:
The working period under which the item was designed to operate.AKPS
Duty Cycle:
Continuous
MRC:
An indication of the feature/s/ of the inclosure.ANPZ
Inclosure Feature:
Totally enclosed
MRC:
The required purpose or application for which the item is designed.ANTN
Specific Use:
Warning light
MRC:
Indicates the specific arrangement in which wire is wound on a form or is formed by winding.AXCP
Winding Type:
Permanent magnet
MRC:
The means of attaching the item.AXGY
Mounting Method:
Face
MRC:
Indicates the type and number of facilities by which the item is mounted.AXHR
Mounting Facility Type And Quantity:
7 threaded hole
MRC:
The means of cooling used to maintain the required operating temperature of the item.BFMF
Cooling Method:
Ambient air
MRC:
The means by which the current is rated.BKPB
Current Rating Method:
Load
MRC:
The government or industrial specification or standard that defines the inclosure feature.BKPQ
Inclosure Specificationification:
Commercial
MRC:
Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
Features Provided:
Frame electrically grounded and vertical mounting position
MRC:
A measurement of the longest dimension of the shaft projection of an item,in distinction from width.CWCS
Length Of Shaft From Housing:
0.375 inches first end
MRC:
A measurement of the longest dimension of the shaft projection of an item,in distinction from width.CWCS
Length Of Shaft From Housing:
0.562 inches second end
MRC:
The speed rating of a rotor,expressed in revolutions per minute.CWFX
Rotor Speed Rating In Rpm:
5000.0 single full load
MRC:
The amount of current for which an item is rated,expressed in amperes.CWGL
Current Rating In Amps:
8.700 single input
MRC:
Indicates the type of connection,rating sequence,and voltage rating at which the item is designed to operate,expressed in volts.CWGQ
Connection Type And Voltage Rating In Volts:
12.0 line to neutral single input
MRC:
An indication of the characteristic(s) of the shaft end.CWHZ
Shaft End Characteristic:
A1 single style first end
MRC:
An indication of the characteristic(s) of the shaft end.CWHZ
Shaft End Characteristic:
A8 single style second end
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
2 wire lead